Global settings ​

nP.global provides the settings for the currently selected analysis context. A context is a saved set of frequencies, times, reference impedance, temperature, and optional two-tone settings. Set the values you need before creating components: each n-port saves its settings when it is constructed.

Default settings ​

PropertyDefaultMeaning
nP.global.fList[2e9]Analysis frequencies in hertz
nP.global.tList[]Sample times in seconds
nP.global.Ro50S-parameter reference impedance in ohms
nP.global.Temp293Component temperature in kelvin
nP.global.twoToneundefinedOptional two-tone input settings

These properties refer to the currently selected context. Changing one affects components created afterward; it does not recalculate components already created.

Frequency list ​

Assign an array of frequencies in hertz, or use fGen(start, stop, points) to make an evenly spaced list that includes both endpoints.

js
nP.global.fList = nP.global.fGen(100e6, 2e9, 51);

var r1 = nP.R(50);
var response = r1.out('s11dB');

This example analyzes 51 frequencies from 100 MHz through 2 GHz. response has a heading row followed by one result row for each frequency.

Each n-port also stores frequency rows in its .spars array. A row starts with its frequency in hertz and then contains that frequency's complex S-parameters. For a two-port, the shape is [frequency, s11, s12, s21, s22]. Two components have matching frequency rows when these frequencies appear in the same order, one for one. nP.nodal() and nP.cascade() require that match when connecting components; having the same number of rows is not enough. When two-tone analysis is enabled, constructors add rows for the additional tone and product frequencies too.

A constructor can use a separate frequency list by accepting fList in its options. Components intended for the same network still need matching rows. See RF Constructors for the component families.

Time list ​

tGen(start, stop, points) creates an evenly spaced array of time samples in seconds, including both endpoints. It requires finite start and stop values, an increasing interval, and at least two points.

js
nP.global.tList = nP.global.tGen(0, 1e-6, 101);

nP.PN() uses tList for its clock times unless you pass a time array directly to PN(). The list must also meet that function's sequence-length requirements. See the Tutorial for a signal-through-circuit example.

Public nP.FFT() requires one uniformly spaced tList time per input sample and replaces fList with the signed output-bin frequencies. nP.invFFT() transforms a spectrum back to complex samples; a spectrum returned by FFT() carries its time grid for .out('real'). For another spectrum, set a matching tList before asking for an inverse-transform output table.

Sampled nP.mod() modes require one tList time per generated waveform sample. VNA-time requires a power-of-two time grid starting at zero and generates a DC-to-Nyquist frequency list for its synthetic impulse. VNA-frequency instead uses a supplied fList (or the selected context's current fList) and needs no time grid. FFT() replaces the selected fList; sampled mod() and VNA-time fill it unless given an fftList array. The default [2e9] remains available for ordinary RF component analysis. A PN clock list is coarser than the expanded sample list used by mod({input: pn}); pass that clock list directly to PN() and set global.tList to the full sample grid before mod().

Reference impedance and temperature ​

Ro is the impedance used as the reference for S-parameters; it defaults to 50 Ω. Temp is the temperature used by components with thermal noise; it defaults to 293 K. Set either value before creating components that use it.

js
nP.global.Ro = 50;
nP.global.Temp = 290;
nP.global.fList = [1e9, 2e9];

var attenuator = nP.Attn(3);

The 3 dB attenuator in this example uses a 50 Ω reference and the selected 290 K temperature for its passive noise model.

Two-tone analysis ​

Set twoTone before constructing components for an intermodulation analysis. fList contains the swept first-tone frequencies; spacingHz is the frequency difference between the first and second tones. p1dBm and p2dBm are their input powers in dBm (decibels relative to 1 mW).

js
nP.global.fList = nP.global.fGen(1e9, 2e9, 11);
nP.global.twoTone = {
    spacingHz: 1e6,
    p1dBm: -30,
    p2dBm: -25
};

var amp = nP.Amp({gainDb: 20, oip3dBm: 30});

Use nP.global.twoTone = undefined when returning to an ordinary frequency sweep. See Intermodulation for product and intercept selectors. For noise measurement conditions, see Noise.

Independent circuits ​

Call nP.global() to start a circuit with a fresh set of the default analysis settings. Save the returned context so you can select that circuit again. Select it with nP.global(savedContext) before creating its components.

js
var circuitA = nP.global();
circuitA.fList = [1e9, 2e9];

var circuitB = nP.global();
circuitB.fList = [3e9, 4e9];

nP.global(circuitA);
var r1 = nP.R(50);

nP.global(circuitB);
var r2 = nP.R(75);

nP.global(circuitA);
var r3 = nP.R(50);

r1 and r3 have rows at 1 and 2 GHz; r2 has rows at 3 and 4 GHz. They cannot be connected in one network because their frequency rows do not match. Assigning circuitA.fList alone does not select circuit A: call nP.global(circuitA) to select it. Switching contexts changes which settings future constructors read; it does not change components already created.