Global settings
nP.global provides the settings for the currently selected analysis context. A context is a saved set of frequencies, times, reference impedance, temperature, and optional two-tone settings. Set the values you need before creating components: each n-port saves its settings when it is constructed.
Default settings
| Property | Default | Meaning |
|---|---|---|
nP.global.fList | [2e9] | Analysis frequencies in hertz |
nP.global.tList | [] | Sample times in seconds |
nP.global.Ro | 50 | S-parameter reference impedance in ohms |
nP.global.Temp | 293 | Component temperature in kelvin |
nP.global.twoTone | undefined | Optional two-tone input settings |
These properties refer to the currently selected context. Changing one affects components created afterward; it does not recalculate components already created.
Frequency list
Assign an array of frequencies in hertz, or use fGen(start, stop, points) to make an evenly spaced list that includes both endpoints.
nP.global.fList = nP.global.fGen(100e6, 2e9, 51);
var r1 = nP.R(50);
var response = r1.out('s11dB');This example analyzes 51 frequencies from 100 MHz through 2 GHz. response has a heading row followed by one result row for each frequency.
Each n-port also stores frequency rows in its .spars array. A row starts with its frequency in hertz and then contains that frequency's complex S-parameters. For a two-port, the shape is [frequency, s11, s12, s21, s22]. Two components have matching frequency rows when these frequencies appear in the same order, one for one. nP.nodal() and nP.cascade() require that match when connecting components; having the same number of rows is not enough. When two-tone analysis is enabled, constructors add rows for the additional tone and product frequencies too.
A constructor can use a separate frequency list by accepting fList in its options. Components intended for the same network still need matching rows. See RF Constructors for the component families.
Time list
tGen(start, stop, points) creates an evenly spaced array of time samples in seconds, including both endpoints. It requires finite start and stop values, an increasing interval, and at least two points.
nP.global.tList = nP.global.tGen(0, 1e-6, 101);nP.PN() uses tList for its clock times unless you pass a time array directly to PN(). The list must also meet that function's sequence-length requirements. See the Tutorial for a signal-through-circuit example.
Public nP.FFT() requires one uniformly spaced tList time per input sample and replaces fList with the signed output-bin frequencies. nP.invFFT() transforms a spectrum back to complex samples; a spectrum returned by FFT() carries its time grid for .out('real'). For another spectrum, set a matching tList before asking for an inverse-transform output table.
Sampled nP.mod() modes require one tList time per generated waveform sample. VNA-time requires a power-of-two time grid starting at zero and generates a DC-to-Nyquist frequency list for its synthetic impulse. VNA-frequency instead uses a supplied fList (or the selected context's current fList) and needs no time grid. FFT() replaces the selected fList; sampled mod() and VNA-time fill it unless given an fftList array. The default [2e9] remains available for ordinary RF component analysis. A PN clock list is coarser than the expanded sample list used by mod({input: pn}); pass that clock list directly to PN() and set global.tList to the full sample grid before mod().
Reference impedance and temperature
Ro is the impedance used as the reference for S-parameters; it defaults to 50 Ω. Temp is the temperature used by components with thermal noise; it defaults to 293 K. Set either value before creating components that use it.
nP.global.Ro = 50;
nP.global.Temp = 290;
nP.global.fList = [1e9, 2e9];
var attenuator = nP.Attn(3);The 3 dB attenuator in this example uses a 50 Ω reference and the selected 290 K temperature for its passive noise model.
Two-tone analysis
Set twoTone before constructing components for an intermodulation analysis. fList contains the swept first-tone frequencies; spacingHz is the frequency difference between the first and second tones. p1dBm and p2dBm are their input powers in dBm (decibels relative to 1 mW).
nP.global.fList = nP.global.fGen(1e9, 2e9, 11);
nP.global.twoTone = {
spacingHz: 1e6,
p1dBm: -30,
p2dBm: -25
};
var amp = nP.Amp({gainDb: 20, oip3dBm: 30});Use nP.global.twoTone = undefined when returning to an ordinary frequency sweep. See Intermodulation for product and intercept selectors. For noise measurement conditions, see Noise.
Independent circuits
Call nP.global() to start a circuit with a fresh set of the default analysis settings. Save the returned context so you can select that circuit again. Select it with nP.global(savedContext) before creating its components.
var circuitA = nP.global();
circuitA.fList = [1e9, 2e9];
var circuitB = nP.global();
circuitB.fList = [3e9, 4e9];
nP.global(circuitA);
var r1 = nP.R(50);
nP.global(circuitB);
var r2 = nP.R(75);
nP.global(circuitA);
var r3 = nP.R(50);r1 and r3 have rows at 1 and 2 GHz; r2 has rows at 3 and 4 GHz. They cannot be connected in one network because their frequency rows do not match. Assigning circuitA.fList alone does not select circuit A: call nP.global(circuitA) to select it. Switching contexts changes which settings future constructors read; it does not change components already created.